Setting out of Buildings

The setting out of a building simply means the marking out of walls, columns, foundation widths and other important elements of a building about to be constructed. Since accuracy is the key, setting out must be undertaking by competent persons. 

Profile Board

Examples of persons that can set out a building are civil engineers and land surveyours.

All setting out work should be thoroughly checked by a different personel using different methods.

It is usually the responsibility of the contractor to set out buildings using information provided in the architectural and structural drawings.

How buildings are set out

The first task in setting out of a building is to establish a base line upon which all setting out will be related. The base line often coincides with the building line.

Setting out building outline

The building line is a line in front of which no construction is permitted by the building/ town planning authorities. For example, the building line for a small estate road can be at a specified distance  of say, 3m, from the road way; 

After the building line is established, a perimeter of profile boards is then set out to surround the actual building area at an offset of about 2m or more. This is to allow adequate room for marking out and excavation of trenches. 

Setting out

The top of the profile boards should be at the same level . 

The corners must be at 90 angles with the use of builders square or theodolite. Diagonal checks must be carried out to confirm accuracy of the setting  out work.

 The next step is to mark out on the profile boards; wall, column and trench positions. Ropes tied on the marked positions  of profile boards and transferred to the corresponding opposite directions (  of marked positions on the opposite profile boards) will show the width of trenches to be dug out.

The width positions can be marked on ground by use of dry lime or similar powder.

Another method is to mark out the exact building outline using corner posts firmly driven into the ground (see 2nd figure).

Corner peg; setting out building outline

With nail driven into the center of the corner posts, cord is tied from one corner to another, connecting  all corners. The outline can then be transferred/ marked on ground using dry lime or similar powder.  Using the building outline, profile boards can then be erected for excavation of trenches and construction of walls and columns

Trench setting out

For larger structures such as large framed buildings, setting out is best carried out by a theodolite or total station equipment. These types of buildings are usually related to a grid system, the intersection of the grid being the center point of an isolated pad footing. The total station can be used to accurately establish the grid system on ground, marking the intersections of grids with stout pegs.

grid method used for setting out columns in large projects

Once grid has been set out, offset pegs or profiles can be fixed clear of subsequent excavation work.

Meaning of some Common Symbols You See in Building Drawings.

Blockwork

Brick wall
Soil

Stone work
Reinforced Concrete
Mass Concrete
Unwrot Timber
Wrot Timber
Dimension Lines
Water Closet
Wash Basin
Urinal
Table & Chair
Switch Doctor
Switch
sink
Single Door
Shower unit
Rain Water Pipe
Pendant switch
Outlines
Hidden Line

Hard Core
Gully
Folding Door
Fluorescent Lamp
Filament lamp
Electricity meter
Drain and Pipe Lines
Double Door
Distribution Board
Grid / Control Line
Bath
2 Way Switch

How to Determine the Size of a Temporary Site Office for a Construction Site

Temporary Site Office / Accommodation

The type of temporary site office/ accommodation to be provided on site is a matter of choice. The contractor can use timber framed huts, prefabricated cabins, mobile offices or even caravans. Generally, separate offices should be provided for the different categories of site staff.

The minimum requirements for construction of this types of office/accommodation is governed by the offices, shop and railway premises acts 1963

Calculation of Office Size  on Construction Site (example)

This example is the calculation of size of building for 6 persons

Assumptions.

Let’s assume an internal height of building of 2.4m,

3.7m2  minimum per person, and 11.5m3 per person.

Office width of 3m.

Calculation

For 6 people, minimum area = 6 x 3.7 =22.2 m2

Similarly;

Minimum volume space= 6 x 11.5 = 69 m3

Since we have assumed the height of building as 2.4m and width as 3m, we can determine the minimum length of building by dividing ;

Minimum volume space/ (height x width) of building;

69/ (3 x 2.4)= 9.58m or say 10m (for 6 persons)

As a check ; 3 x 10 = 30m2 which is greater than 22.2m2